| Chambers | 3110-585 |
Pull Rod
| Upper Pullrod, Type Cm (5/8 in connection with 1/4 in clevis pin) to Pneumatic Connection.
Capacity: 1 kN (100 kgf, 225 lbf)
Effective length: 361 mm (14.2 in). Diameter: 31.7 mm (1.25 in).
Chamber filler plug not included; Ref. 3110-525
Checknut not used.
| 1 |
Contact Instron About Item
|
| Chambers | 3110-710 |
Push Pull Rod
| Push/Pull Rod.
Type Om to Of. 322mm (12.7 inch) long. | 1 |
Contact Instron About Item
|
| Couplings | 2501-094 |
Tension Coupling
| Tension Coupling, Type Om (12 mm connection with 6 mm clevis pin) to Cf (5/8 in connection with 1/4 in clevis pin). Capacity: 2 kN. | 1 |
Contact Instron About Item
|
| Couplings | 2501-157 |
Tension Coupling
| Tension Coupling, Type OOm (6 mm connection with 2.6 mm clevis pin) to Cf
(5/8 in connection with 1/4 in clevis pin). | 1 |
Contact Instron About Item
|
| Couplings | 2501-351 |
Coupling for 2713-006 grips
| Adaptor set for 2713-006 grips to Instron machines. Includes two Type Om, one Type Dm Adapters. | 1 |
Contact Instron About Item
|
| Couplings | 8005-042 |
Attachment Kit
| Attachment Kit. Type IIm LH (M48X2) to IIm RH (M48X2). Includes Wedge
Washers. | 2 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-101 |
2630-101
| Strain Gauge Extensometer, 10 mm gauge length, +/-10% maximum | 1 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-105 |
2630-105
| 25 mm gauge length, +/-10% travel (Static) | 5 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-107 |
2630-107
| 25mm gauge length 100% travel (Static) | 1 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-108 |
2630-108
| 1in gauge length, 10% travel (Static) | 1 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-109 |
2630-109
| Strain Gauge Extensometer, 1 in gauge length, +50%, -10% travel (Static) | 1 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-110 |
2630-110
| Strain Gauge Extensometer, 1 in gauge length, +100%, -10% travel (Static) | 2 |
Contact Instron About Item
|
| Extensometers | LCR-UEX-2630-115 |
2630-115
| 2in gauge length 50% travel (Static) | 1 |
Contact Instron About Item
|
| Extensometers | U380 |
B3M
| Reconditioned Model B3M extensometer, 1" GL, 2% Measuring Range
Rounds: .05" to .505"
Flats: .005" to 0.500" thick x 0.500" wide | 1 |
Contact Instron About Item
|
| Extensometers | U383 |
PS6M
| Reconditioned Model PS6M | 1 |
Contact Instron About Item
|
| Extensometers | U415 |
Series E
| Reconditioned Series E Extensometer. 2" GL with +50%/-25% travel | 1 |
Contact Instron About Item
|
| Extensometers | U592 |
W-6280-8
| Long GL (8") Extensometer. 12.5% Strain.
Rounds: 0 to 1"
Flats: 0 to 0.5" thick x 1.25" wide | 1 |
Contact Instron About Item
|
| Extensometers | U594 |
M300
| Used M300 Automatic Extensometer for use on a LX system. GL Range: 10mm to 200mm.
Rounds: 80mm max
Flats: 30mm thick & 50mm wide max | 1 |
Contact Instron About Item
|
| Extensometers | U622 |
Series E
| Extensometer E-Series I3543, 250mm guage length, 100mm travel | 1 |
Contact Instron About Item
|
| Faces | 2702-004 |
Faces
| Smooth faces. 1 x 1 inch
Used with grips
2712-002, 2732-001, 2710-001
B Style | 1 |
Contact Instron About Item
|
| Faces | 2702-031 |
Faces, Smooth
| Faces, Smooth Ground. 25 mm wide x 25 mm high (1 x 1 in.) . Set of 4 faces.
For 2710-002, 103, 104, 2712-003, 004, 015, 016, 018, 020, and 2732-003,
004, 008, 009
Pneumatic Side Action Grips, and Screw Side Action Grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-033 |
Faces, Serrated. 25 mm wide x 25 mm high
| Faces, Serrated. 25 mm wide x 25 mm high (1 x 1 in.)
Set of 4 faces.
For 2710-002, 103, 104, 2712-003, 004, 015, 016, 018, 020, and 2732-003,
004, 008, 009
Pneumatic Side Action Grips, and Screw Side Action Grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-034 |
Faces
| Faces, Smooth Ground. 75 mm wide x 25 mm high (3 x 1 in.) For 2712-003, 2732-003, 2712-004, 2732-004, 2712-015, 2712-016 Pneumatic Side Action Grips, and 2710-002, S1-15455 Screw Action Grips. Set of 4 faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-042 |
Faces
| Hi temp faces. 1 x 1 inch.
Used with grips
2712-002, 2732-001, 2710-001
B Style | 2 |
Contact Instron About Item
|
| Faces | 2702-106 |
Faces, Smooth
| Faces, Smooth Ground. 25 mm x 25 mm (1 x 1 in). Specimen thickness: 0 -
20 mm. For 2712-017 Pneumatic Side Action Grips and 2712-012 Pneumatic
Side Action Grips. Set of four faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-130 |
Faces
| Faces, Smooth Ground. 25 mm wide x 25 mm high (1 x 1 in). For 2710-004
Screw Action Grips. Set of four faces. | 1 |
Contact Instron About Item
|
| Faces | 2702-140 |
Faces
| Jaw faces, smooth-ground, 50 mm wide x 30 mm high (2.0 in x 1.2 in).
For specimens up to 15 mm (0.6 in) thickness.
For 2710-203, 2710-204, 2710-205 grips. | 1 |
Contact Instron About Item
|
| Faces | 2702-142 |
Jaw Faces
| Jaw faces, rubber-coated, 50 mm wide x 30 mm high (2.0 in x 1.2 in).
For specimens up to 15 mm (0.6 in) thickness.
For 2710-203, 2710-204, 2710-205 grips | 1 |
Contact Instron About Item
|
| Faces | 2703-071 |
Faces
| Threaded faces. 16T per inch
16mm to 19mm(0.625 to 0.75 inch) opening
Used with grips 2716-002, 2736-002 | 1 |
Contact Instron About Item
|
| Faces | 2703-171 |
Faces
| Serrated faces. 25mm
Use with grips
2716-016, 2716-017 | 1 |
Contact Instron About Item
|
| Faces | 2703-182 |
Faces
| Faces, Vee Serrated. Specimen thickness range: 6-17.8 mm.
For 2716-110, 111, 120, 121 Pneumatic Wedge Action Grips.
Set of four. | 1 |
Contact Instron About Item
|
| Faces | 2703-544 |
Faces
| Flat serrated jaw faces 100mm wide for gripping flat specimens 31-42mm thick
(set of 4 faces)
For use with 2742-501 grip | 1 |
Contact Instron About Item
|
| Faces | 2703-555 |
Faces
| Serrated faces. 100mm wide
25 to 32mm (1.0 to 1.25inch) opening
Used with grips 2742-524 | 1 |
Contact Instron About Item
|
| Faces | W-5181-A |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 0 - 15 mm (0 - 0.59 in).
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5181-B |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 15 - 30 mm (0.59 - 1.18 in)
For W-5180, W-5380 bodies and 150DX-G7, 300DX-G7 crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5181-C |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 30 - 45 mm (1.18 - 1.77 in)For W-5180, W-5380 bodies and 150DX-G7, 300DX-G7 crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-B |
Faces
| Faces, Vee Serrated 1.25 mm pitch grooves (20 TPI).
Specimen Diameter: 5 - 15 mm (0.196 - 0.59 in.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-C |
Faces
| Faces, Flat Serrated 1.25 mm pitch grooves (20 TPI), 70 mm (2.75 in) wide.
Specimen Thickness: 30 - 45 mm (1.18 - 1.77 in.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Faces | W-5185-D |
Faces
| Faces, Vee Serrated 2.5 mm pitch grooves (10 TPI).
Specimen Diameter: 30 - 45 mm (1.18 - 1.77 in)
Note: Maximum Jaw face separation fully open-front grip loading is 37 mm
(1.46 in). Specimens of greater diameter require end loading.
Jaw Faces for W-5180, W-5380 WEDGE GRIP bodies and 150DX-G7(A thru-D), 300DX-G7 (A thru D)
crossheads | 1 |
Contact Instron About Item
|
| Fixtures | 2810-411 |
Micro 3 Point Bend Fixture
| Micro 3 Point Bend Fixture
Adjustable Span: 3 mm to 10 mm.
Capacity 1 kN (225 lb, 100 kgf).
Temperature range: -75°C to 300°C (-103°F to 572°F). Maximum specimen
width: 20 mm (0.79 in).
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
ref. S4843A | 1 |
Contact Instron About Item
|
| Fixtures | PR10754-8 |
Dies Shear fixture
| Die Shear fixture with 10 mm.
1 kN Capacity | 1 |
Contact Instron About Item
|
| Grip Accessories | 2701-042 |
Air Distribution Kit
| Air Distribution Kit, External. For use with 2712-002, 003, 004, 014, 015, 018,
019, 020, and 2712-04x grips only.
Includes hoses and fittings with 1/4 NPTM end connection. | 1 |
Contact Instron About Item
|
| Grips | 2710-101 |
Screw Side Action Grip
| Advanced Screw Side-Action Grips. Capacity: 100 N (10 kgf, 20 lbf).
Temperature Range: -70 °C to +125 °C (-94 °F to +257 °F)
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin)
Features:
- Dual screw actuation with graduated cylinders
- Snap-on jaw face mechanism with self-alignment
- Wide opening suitable for specimen thicknesses up to 30 mm (1.2 in)
Requires jaw faces | 1 |
Contact Instron About Item
|
| Grips | 2711-001 |
Fiber Clamps
| Fiber Clamps. 5N
Upper Type A Lower Type D | 3 |
Contact Instron About Item
|
| Grips | 2712-001 |
Pneumatic Side Action Grips
| Pneumatic Side Action Grips. Capacity: 5 N (1.0 lb, 500gm).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: 3.96 mm (0.156 in).
Upper fitting: Type A (Hook).
Lower fitting: Type Dm (1.25 in connection with 1/2 in clevis pin).
Includes one pair of 9.5 x 9.5 mm smooth faces.
Requires an Automatic Air Control Kit or Pneumatic Foot Switch | 2 |
Contact Instron About Item
|
| Grips | 2712-013 |
Pneumatic Side Action Grips
| Pneumatic Side Action Grips. Capacity: 5 N (1.0 lb, 500gm).
Temperature range: -29 °C to 80 °C (-20 °F to 176 °F).
Maximum specimen thickness: 3.96 mm (0.156 in).
Upper and lower fittings: Type Om (12 mm connection with 6 mm clevis pin).
Includes 9.5 x 9.5 mm smooth faces.
Requires an Automatic Air Control Kit or Pneumatic Foot Switch | 1 |
Contact Instron About Item
|
| Grips | 2712-041 |
Pneumatic Side Action Grips.
| Pneumatic Side Action Grips. Capacity: 1 kN (100 kg, 225lb).
Temperature range: -20 °C to +100 °C (-4 °F to +212°F).
Maximum specimen thickness: 13mm (0.5 in)*
*Depends on jaw faces selected
Upper and lower fittings: 6 mm clevis pin, male | 2 |
Contact Instron About Item
|
| Grips | 2712-042 |
Pneumatic Side Action Grip
| Pneumatic Side Action Grips. Capacity: 2 kN (200 kg, 450 lb,).
Temperature range: -20 °C to +100 °C (-4 °F to +212°F).
Maximum specimen thickness: 20mm (0.75 in)*
*Depends on jaw faces selected
Upper and lower fittings: 6 mm clevis pin, male.
Requires jaw faces and an Air Distribution Kit.
Optional Air Control Kit with footswitch is available. | 3 |
Contact Instron About Item
|
| Grips | 2712-045 |
Pneumatic Side Action Grips
| Pneumatic Side Action Grips. Capacity:5kN (500 kg,1250 lb.)
Temperature range: -20 °C to 100 °C (-4 °F to 212°F).
Maximum specimen thickness: 26mm (1 in)*
*Depends on jaw faces selected
Upper and lower fittings: 0.5 in clevis pin, male.
Requires jaw faces and an Air Distribution Kit.
Optional Air Control Kit with footswitch is available. | 2 |
Contact Instron About Item
|
| Grips | 2712-046 |
Pneumatic Side Action Grips.
| Pneumatic Side Action Grips. Capacity: 10 kN (1000 kg, 2250 lb,).
Temperature range: -20 °C to +100 °C (-4 °F to +212°F).
Maximum specimen thickness: 26mm (1 in)*
*Depends on jaw faces selected
Upper and lower fittings: 0.5 in clevis pin, male.
Requires jaw faces and an Air Distribution Kit.
Optional Air Control Kit with footswitch is available. | 4 |
Contact Instron About Item
|
| Grips | 2713-001 |
Self Tightening Roller Grips
| Self Tightening Roller Grips. Capacity: 1.0 kN (200 lb, 100 kg).
Temperature range: -73 °C to 150 °C (-100 °F to 302 °F).
Upper fitting: Type Cm (5/8 in connection with 1/4 in clevis pin).
Lower fitting: Type Dm (1.25 in connection with 1/2 in clevis pin).
Includes rubber covered snubbing rollers and smooth snubbing rollers.
For elastomeric samples.
*Rubber Rollers ONLY | 1 |
Contact Instron About Item
|
| Grips | 2715-002 |
Capstan grip faces
| Smooth faces for 2715-001 | 1 |
Contact Instron About Item
|
| Grips | 2716-010 |
Mechanical Wedge grip
| Wedge Action Grips, Capacity: 5 kN (1,000 lb, 500 kg).
Temperature range: -150 °C to 250 °C (-240 °F to 480 °F).
Maximum specimen size is face determined.
Upper and lower fittings: Type Dm. (1.25 in connection with 1/2 in clevis pin).
Requires faces | 1 |
Contact Instron About Item
|
| Grips | 2717-056 |
Grips
| Self-Aligning Tension Grip Body. Capacity: 250 kN (50,000 lb, 25,000 kg).
For threaded and shouldered specimens.
Temperature range: 0 °C to 150 °C (32 °F to 300 °F).
Upper and lower fittings: Type IIm LH (M48x2)
Requires grip heads to suit specimen. | 1 |
Contact Instron About Item
|
| Grips | 2732-008 |
Grips
| Pneumatic Side Action Grips. Capacity: 1 kN (200 lb, 100 kg).
Temperature range: -73 °C to 316 °C (-100 °F to 600 °F).
Maximum specimen thickness: *6.35 mm (0.25 in)
*Reduced by 1.6 mm (0.062 in) with rubber coated faces.
Upper and lower fittings: Pneumatic connection.
Requires faces, pneumatic pullrods and an Automatic Air Control Kit or
Pneumatic Foot Switch.
Maximum face height: 38 mm (1.5 in) | 2 |
Contact Instron About Item
|
| Grips | CP103444 |
Hydraulic Wedge Action Grip
| Hydraulic Wedge Action Grips. Capacity 300 kN (67,500 lbf, 30,000 kgf)
Specimen Range:
- Flats: 0 - 50 mm thick (0 - 2.0 in) x 70 mm (2.75 in) wide
- Rounds: 3 - 40 mm (0.118 - 1.57 in) diameter
Minimum Specimen Length without the use of an extensometer is 270 mm
(10.63 in)
Ambient temperature use only.
Upper and Lower Fittings: Type IIfRH (M48 x 2)
Weight Per Grip Body 123 kg (270 lb)
Grip Body Dimensions W x L x D: 445 x 302 x 127 mm (17.5 x 11.875 x 5 in)
Effective Length using standard threaded mounting:
Upper - 329 mm (13.0 in)
Lower - 352 mm (13.8 in)
Grip faces sold separately use: W-5181 & W-5185 series grip faces
Notes:
1) Hydraulic hoses, manifolds and mounting hardware when purchased with a
new 300LX or 300KN testing system are provided. (Select mounting options
corresponding to load frame and test space option of the machine grips are to
be used on. Consult IPG Business team for all other applications.)
2) Note: If integrating these grips on an LX frame, the frame must be
configured with a minimum of 300 mm (1 foot) of extended height in order to
accomodate calibration fixtures. | 1 |
Contact Instron About Item
|
| Grips | U593 |
W-5021 & W-5012
| Used 100kN (22,500 Lbs) T-Grip Bodies & flat jaws (16 TPI diamond cut). Flats: Up to 1/2" thick x 1" wide. | 1 |
Contact Instron About Item
|
| Grips | W-1409-A |
600DX, or 120HVL Flat Grip Jaw Set
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $2080, ON SALE FOR $1040!!!
Set of (4) wedge grip jaws for flat specimens from 0 to 45 mm (1.75 in) thick by up to 70 mm (2.75 in) wide. Tooth Profile: Diamond cut, 16 TPI (teeth per inch) | 2 |
Contact Instron About Item
|
| Grips | W-1563 |
200 HVL Grips For Round Specimens
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3640, ON SALE FOR $1820!!!
Set of (4) Vee wedge grip jaws for round specimens from 0.5 in (12.7 mm) to 2.25 in (57 mm) diameter. Tooth Profile: Horizontal cut, 16 TPI (teeth per inch)
| 2 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2519-106 |
2519-106
| 2kN S-Beam type load cell | 2 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2525-815 |
2525-815
| 2.5 N Drop Through Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-UEX-2530-439 |
2530-439
| 5 N Low Profile Static | 8 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-101 |
2519-101
| 10N S-Beam Static | 15 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-102 |
2519-102
| 50N S-Beam Static | 8 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-103 |
2519-103
| 100N S-Beam Static | 16 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-105 |
2519-105
| 1kN S-Beam Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2519-107 |
2519-107
| 5kN S-Beam Static | 9 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-804 |
2525-804
| 10kN Drop Through Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-805 |
2525-805
| 5kN Drop Through Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-810 |
2525-810
| 30kN Drop Through Style Static | 3 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2525-816 |
2525-816
| 500N Drop Through Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2527-130 |
2527-130
| 1kN Sandwich Style Dynamic (Dynacell) | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2527-131 |
2527-131
| 250 N Sandwich Style Dynamic (Dynacell) | 3 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-405 |
2530-405
| 5kN Low Profile Static | 13 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-418 |
2530-418
| 2kN Low Profile Static | 1 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-427 |
2530-427
| 100N Low Profile Static | 13 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-428 |
2530-428
| 10N Low Profile Static | 5 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-437 |
2530-437
| 50N Low Profile Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-443 |
2530-443
| 10kN Low Profile Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-444 |
2530-444
| 30kN Low Profile Static | 2 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2530-445 |
2530-445
| 50kN Low Profile Static | 7 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2580-107 |
2580-107
| Static Load Cell +/-2kN | 4 |
Contact Instron About Item
|
| Load Cells | LCR-ULC-2580-108 |
2580-108
| Static Load Cell +/-5kN | 4 |
Contact Instron About Item
|
| Load Cells | W-5535-8 |
5kN Load Cell
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3050, ON SALE FOR $1525!!!
Heavy Duty Tension/Compression Load Cell, Capacity 5 kN (500 kg, 1,100 lb.)
-Mounting, and adapter connection, M16 female
- Minimum 300% overload capacity
- Integral load stops minimize chance of cell damage during overload conditions.
- Equipped with 25 pin type D style connector for 3300, or 5500 test systems
| 1 |
Contact Instron About Item
|
| Load Cells | W-5535-9 |
10kN Load Cell - New
| 50% OFF SALE THROUGH DECEMBER 15TH. NEW OLD STOCK - LIST PRICE - $3280, ON SALE FOR $1640
Heavy Duty Tension/Compression Load Cell, Capacity 10 kN (1,000 kg, 2,200 lb.)
- Accuracy +/- 0.5% of reading from 1% to 100% of load cell capacity when used with SF Series Spring Testers
- Mounting connection, M16 female
- Adapter connection M16 female
- Minimum 300% overload capacity
- Integral load stops minimize chance of cell damage during overload conditions.
| 1 |
Contact Instron About Item
|
| Platens | 2501-107 |
Platen
| Compression Platen. 50N
13 sq cm (2 sq inch) 40.6mm (1.6 inch) diameter.
Type Om connection | 1 |
Contact Instron About Item
|
| Platens | 2840-112 |
Platen
| Fatigue Rated Spherical Seat, Capacity 500kN (110 kip) Static / 250kN (56 kip)
Dynamic.
- For Use With 2840-118,-119 Or -110 Platens
- Includes adaptor to M30 x 2 right hand or M48 x 2 right hand compression
platen
- Mechanical interface: M48 x 2 right hand female thread
Quantity: 1 seat | 1 |
Contact Instron About Item
|